			PMconsole 3.5 Release Note


	PMconsole(TM) release 3.5 is available for the following platforms:

	-  SunOS 4.1.4
	-  Solaris 2.5
	-  Solaris/X86 2.5.1
	-  AIX RS/6000 3.2.5
	-  BSD/OS 2.0
	-  DEC Alpha OSF/1 3.0
	-  HP/UX 10.03
	-  Linux 1.2.13 (ELF)
	-  SGI Irix 5.2
	-  Windows 95
	-  Windows NT 4.0

	As of this release, PMconsole is no longer supported on Windows
	3.1.1 and Windows NT 3.51


________________________________________________________________________
FEATURES

PortMaster 3 Integrated Access Server support

	PMconsole release 3.5 supports configuration of the new 
	PortMaster(TM) 3 Integrated Access Server.  Earlier versions of
	PMconsole cannot be used with the PortMaster 3.

ComOS 3.5 support

	When ComOS 3.5 on the PortMaster 2, IRX and Office Router is released,
	PMconsole 3.5 can be used to configure those.

New utility to dump filters

	pmdumpfilter displays the contents of all filters that reside on the
	PortMaster.  To use pmdumpfilter, specify the following:

		pmdumpfilter PortMasterName Password

	You can redirect the output into a file as follows:

		pmdumpfilter PortMasterName Password >File

BOOTP supported in pminstall

	The "PortMaster Internet Address Setup" option in pminstall
	now uses BOOTP on all operating systems, including Win95 and WinNT.

Console Port

	PMconsole now displays the console port (C0) for PM-2i 

PMconsole supports new features 

	See ComOS release notes for more information on these features,
	which can now be configured with PMconsole release 3.5.  Some
	of these features may not be available in some versions of
	ComOS.  PMconsole release 3.5 can also be used to configure
	previous releases of ComOS.

	PAP, CHAP, and Serial Admin can now be enabled or disabled
	in the global table.
	 
	5ESS-PTP and various new ISDN switch types are supported.

	On dial-in ports, maximum idle time can now be set in minutes
	or seconds.

	On synchronous ports, Annex-D LMI may now be set for Frame Relay.

	In the User Table, maximum ports, session timeouts, and idle
	timeouts can be set.  Idle timeouts can be specified in minutes
	or seconds.

	For ISDN calls, the phone number, username, and password can be
	specified for a dial out location, to make it easier for the
	PortMaster to authenticate itself using PAP or CHAP when
	dialing out to other sites.  CHAP can be enabled or disabled in
	the Location Table.

	Multilink and Voice in the Location Table are now supported.

	ComOS 3.5 supports variable length subnet masks (VLSM), so PMconsole 3.5
	allows you to specify VLSM-style routes.  For example, to specify that
	only hosts 192.168.4.1 through 192.168.4.30 should be routed through
	192.168.4.1, you can now use the route:

	192.168.4.0/27 192.168.4.1 1
	
	
________________________________________________________________________
RESTRICTIONS

	Filters from ComOS 3.5 on the PortMaster 3 cannot be edited
	with PMconsole.  This will be fixed in ComOS 3.5.1 on the
	PortMaster 3 and 3.5 on all other platforms.  If you attempt to
	edit filters on a PortMaster 3 running ComOS 3.5, PMconsole
	will display a warning message.

	PMconsole 3.5 cannot delete routes from the static routing table.

________________________________________________________________________
INSTALLATION - UNIX

	To install PMconsole 3.5 from the CD, mount the CD as /cdrom
	and run /cdrom/unix/setup to install.

	To get PMconsole 3.5 using FTP and install it, follow these
	instructions, replacing sun4 with the name of your platform
	instead.  The software is usually installed in /usr/portmaster
	but may be installed anywhere.

	cd /usr/tmp
	ftp ftp.livingston.com
		anonymous
		(enter your email address; it will not echo)
		binary
		cd pub/le/software/sun4
		get pm_3.5_sun4.tar
		quit
	mkdir /usr/portmaster
	cd /usr/portmaster
	tar xf /usr/tmp/pm_3.5_sun4.tar
	rm /usr/tmp/pm_3.5_sun4.tar

	PMconsole 3.5 also includes the Livingston RADIUS(tm) Server
	release 2.0 in binary form.  For information on RADIUS source
	see <http://www.livingston.com/Forms/radiusform.cgi>.

________________________________________________________________________
INSTALLATION - WINDOWS

	To install PMconsole for Windows from the CD 
	on Microsoft Windows 95 and Windows NT 4.0:

	1.  Click the pc folder.

	2.  Click the pmconsole folder.

	3.  Double-click on setup.exe to install PMconsole.

	To install PMconsole for Windows from the FTP site, FTP the file
	ftp://ftp.livingston.com/pub/le/software/pc/pmw35kit.exe and
	double-click on it to install.

________________________________________________________________________

Copyright and Trademarks

	Copyright 1996 Livingston Enterprises, Inc. All rights reserved.

	The product names, "ChoiceNet", "ComOS," "IRX," "PortMaster,"
	"PMconsole," "RADIUS," and "True Digital" are trademarks
	belonging to Livingston Enterprises, Inc.

	All brand product names mentioned in this document are trademarks
	or registered trademarks of their respective manufacturers.

Notices

	Livingston Enterprises, Inc. makes no representations or
	warranties with respect to the contents or use of this manual,
	and specifically disclaims any express or implied warranties of
	merchantability or fitness for any particular purpose. Further,
	Livingston Enterprises, Inc. reserves the right to revise this
	publication and to make changes to its content, any time,
	without obligation to notify any person or entity of such
	revisions or changes.

Contacting Livingston Technical Support

	Every Livingston PortMaster or IRX product comes with lifetime
	software technical support and a one year hardware warranty.
	Livingston Enterprises provides technical support via voice,
	FAX, and electronic mail. Technical support is available Monday
	through Friday 6am-5pm Pacific Time (GMT-8).

	To contact Livingston technical support by voice, dial
	1-800-458-9966 within the US or 1-510-426-0770 outside the US,
	by FAX, dial 1-510-426-8951, by electronic mail, send mail to
	support@livingston.com, and through the World Wide Web at
	http://www.livingston.com/.

	To contact Livingston technical support by voice, dial
	1-800-458-9966 within the USA, Canada, or the Caribbean, or
	1-510-426-0770 from  elsewhere; by FAX, dial 1-510-426-8951; by
	electronic mail, send mail to support@livingston.com.  Or
	contact Livingston technical support on the World Wide Web at
	http://www.livingston.com/ .