2000/27/11

		ComOS 4.2c2 Release Note
		   for the PortMaster 4

 
_______________ Introduction

The Lucent Technologies ComOS(R) 4.2c2 software release is now 
available for general availability (GA) for the PortMaster(R) 4 
Integrated Access Concentrator. This release note applies only to 
the PortMaster 4.

This release is provided at no charge to all Lucent customers. This
release note documents commands and features added and bugs 
fixed between ComOS 4.2 and ComOS 4.2c2 on the PortMaster 4.   

ComOS 4.2c1 was provided to a few customers, but was never 
officially released.  For clarity, this release note includes two "Bugs 
Fixed" sections -- one for bugs fixed in ComOS 4.2c1 and one for 
bugs fixed in ComOS 4.2c2.

This release contains the same modem code as did ComOS 4.2 for 
the PortMaster 4.

Before upgrading, thoroughly read "Upgrade Instructions."

 
_______________ Contents

Introduction
Supporting Documents
Bug Fixed in ComOS 4.2c2
Bugs Fixed in ComOS 4.2c1
Improvements to ComOS 4.2c2
	L2TP LNS Improvements
	Collect Call Blocking Improved for Brazilian Customers
Upgrade Instructions
Technical Support


_______________ Supporting Documents

* PortMaster 4 User Manual Addendum 

For detailed installation and configuration instructions, simple
troubleshooting instructions, and command descriptions for 
ComOS 4.2c2 on the PortMaster 4, see this addendum at 
http://www.livingston.com/tech/docs/manuals.html.

* PortMaster 4 Installation Guide

* PortMaster 4 Configuration Guide

* PortMaster 4 Command Line Reference 

For general PortMaster 4 documentation, see these manuals, also 
at http://www.livingston.com/tech/docs/manuals.html. (Or see the 
PortMaster 4 User Manual binder, which contains these manuals 
in printed form).

* MIB for PortMaster 4 SNMP Agent

For ComOS 4.2 extensions to the PortMaster Management Information 
Base (MIB), go to ftp://ftp.livingston.com/pub/le/snmp/le42.mib.


_______________ Bug Fixed in ComOS 4.2c2

ComOS 4.2c2 fixes a rare problem in which the Ether1 interface stopped 
transmitting packets after the Ethernet chip encountered a memory 
contention error. This release improves error reporting and recovery 
algorithms so that other similar but even more unlikely problems with 
Ether1 will be reported and handled gracefully.


_______________ Bugs Fixed in ComOS 4.2c1

The following bugs were fixed in ComOS 4.2c1:

* Previously, timing problems that occurred during the dismantling of 
Layer 2 Tunneling Protocol (L2TP) sessions caused various problems,  
including reboots of the Quad T1 or Tri E1 boards. These timing 
problems are now fixed.

* Previously, the disconnection of one channel of a Multilink PPP 
connection occasionally created problems on the remaining channels, 
which sometimes caused a Quad T1 or Tri E1 board to reboot. This 
behavior has been corrected.

* On a PortMaster 4 functioning as an L2TP access concentrator (LAC),  
an unstable line carrying L2TP sessions previously caused the system to 
crash. The system would reboot when trying to report multiple harmless 
low-memory references. This behavior has been corrected.


______________ Improvements to ComOS 4.2c2

The following commands and improvements were added in ComOS 4.2c1 
and retained in ComOS 4.2c2.

_______ L2TP Improvements

The number of L2TP sessions supported when the PortMaster 4 is 
functioning as an L2TP network server (LNS) has been increased 
to between 62 and 64 L2TP sessions per Quad T1 board.  In 
ComOS 4.2, only about 46 to 50 L2TP session were supported per 
Quad T1 board.  


_______ Collect Call Blocking Improved for Brazilian Customers

For a Tri E1 board that is already configured to multifrequency 
robbed bit signaling (MFR2) mode, the keywords "cbwait1" and 
"cbwait2" in the "set Line0 mfr2" command allow you to change
collect call blocking on a per-line basis. 

These keywords are useful only for MFR2 profile 6, which is 
used in Brazil for collect call blocking.

For example:

       set line0 mfr2 cbwait1 4
       set line0 mfr2 cbwait2 20

The "cbwait1" and "cbwait2 values are specified in system ticks 
(1 tick = 55 ms). The default value for cbwait1 is 3 (165 ms). The default 
value for cbwait2 is 18 (1 second).
       
If the value of either keyword is set to 0, the default value is used.
Either value cannot be higher than 255 ticks.

For these values to take effect, you must save the configuration 
and reboot the Tri E1 board.


_______________ Upgrade Instructions

You can upgrade your PortMaster 4 using PMVision 1.11, or pmupgrade
from PMTools 4.4. Alternatively, you can upgrade using the older
programs pminstall 3.5.3, PMconsole 3.5.3, or PMconsole for Windows
3.5.1.4. You can also upgrade using TFTP with the "tftp get" command
from the PortMaster command line interface.

See ftp://ftp.livingston.com/pub/le/software/java/pmvision111.txt for
installation instructions for PMVision 1.11.

*** CAUTION! If the upgrade fails, do NOT reboot! Contact 
*** Lucent NetworkCare(TM) technical support without rebooting.

The upgrade process on the PortMaster 4 erases the configuration area
from nonvolatile memory and saves the current configuration into
nonvolatile memory. Never interrupt the upgrade process, or loss of
configuration information can result. This upgrade does not otherwise
affect your stored configuration in the PortMaster 4.

The installation software can be retrieved by FTP from
ftp://ftp.livingston.com/pub/le/software/, and the upgrade image can be
found at ftp://ftp.livingston.com/pub/le/upgrades/:

ComOS		Upgrade Image	Product
_________ 	_____________	_______________________________
4.2c2		pm4_4.2c2 	PortMaster 4

__________________________________________________________


	Copyright and Trademarks

Copyright 2000 Lucent Technologies Inc. All rights reserved.

PortMaster, ComOS, and ChoiceNet are registered trademarks of Lucent
Technologies Inc. PMVision, IRX,  PortAuthority, NetworkCare, 
and eSight are trademarks of Lucent Technologies. PolicyFlow is a 
service mark of Lucent Technologies Inc. All other marks are the 
property of their respective owners.

	Notices

Lucent Technologies Inc. makes no representations or warranties with 
respect to the contents or use of this publication, and specifically disclaims
any express or implied warranties of merchantability or fitness for any
particular purpose. Further, Lucent Technologies Inc. reserves the 
right to revise this publication and to make changes to its content, any 
time, without obligation to notify any person or entity of such revisions or
changes.

	Contacting Lucent NetworkCare Technical Support

Lucent NetworkCare Professional Services provides PortMaster technical
support through the World Wide Web at http://www.esight.com/. Click 
"Contact Us" on the eSight(TM) home page for support information.

Customers, sales channel partners, and value-added resellers (VARs) 
with active service agreements or contracts can call the following 
telephone numbers for technical support:

o Within the United States (including Alaska and Hawaii), dial 
1-800-272-3634.

o Outside the United States, dial +1-510-769-6001.

Specify that you are running ComOS 4.2c2 when reporting problems 
with this release.